D-PB-1

STANDARD DETAILS FOR CONCRETE PIPE INSTALLATION
D-PB-1

(Click image to open PDF)

Latest Revision Note

03/01/2023    REVISED GENERAL NOTE (G1).

Related Standard Drawings

DRAWINGDESCRIPTIONREMARKS
D-PB-3INDUCED TRENCH SOIL EMBANKMENT FOR PIPE CULVERT INSTALLATIONSEE FOR MINIMUM CONSTRUCTION COVER DEPTHS
D-PE-1TYPE "A" CONCRETE ENDWALLS FOR ROUND PIPE (PIPE SIZES 36" TO 78", ALL SKEWS, 2:1 SLOPE)CROSS DRAIN ENDWALLS PLACED OUTSIDE THE CLEAR ZONE MAY USE TYPE A
D-PE-4STRAIGHT CONCRETE ENDWALLS (PIPE SIZES 18" TO 30")CROSS DRAIN ENDWALLS PLACED OUTSIDE THE CLEAR ZONE MAY USE STRAIGHT HEADWALL
D-PE-9TYPE "B" CONCRETE ENDWALLS FOR ROUND AND SIDE TAPERED INLETS (PIPE SIZES 15" TO 78", ALL SKEWS, 2:1 AND 4:1 SLOPES)CROSS DRAIN ENDWALLS PLACED OUTSIDE THE CLEAR ZONE MAY USE TYPE B
D-PE-9ATYPE "B" CONCRETE ENDWALLS FOR ROUND INLETS, DETAILS & QUANTITIES (PIPE SIZES 15" TO 78", ALL SKEWS, 2:1 AND 4:1 SLOPES)CROSS DRAIN ENDWALLS PLACED OUTSIDE THE CLEAR ZONE MAY USE TYPE B
D-PE-9BTYPE "B" CONCRETE ENDWALLS FOR SIDE TAPER INLETS, DETAILS & QUANTITIES (PIPE SIZES 15" TO 78", ALL SKEWS, 2:1 AND 4:1 SLOPES)CROSS DRAIN ENDWALLS PLACED OUTSIDE THE CLEAR ZONE MAY USE TYPE B
D-PE-9CTYPE "B" CONCRETE ENDWALLS, BILL OF STEEL FOR CONCRETE PIPES (PIPE SIZES 15" TO 78", ALL SKEWS, 2:1 SLOPE)CROSS DRAIN ENDWALLS PLACED OUTSIDE THE CLEAR ZONE MAY USE TYPE B
D-PE-9DTYPE "B" CONCRETE ENDWALLS, BILL OF STEEL FOR CONCRETE PIPES (PIPE SIZES 15" TO 78", ALL SKEWS, 4:1 SLOPE)CROSS DRAIN ENDWALLS PLACED OUTSIDE THE CLEAR ZONE MAY USE TYPE B
D-PE-9ETYPE "B" CONCRETE ENDWALLS, BILL OF STEEL FOR STEEL PIPES (PIPE SIZES 15" TO 78", ALL SKEWS, 2:1 SLOPE)CROSS DRAIN ENDWALLS PLACED OUTSIDE THE CLEAR ZONE MAY USE TYPE B
D-PE-9FTYPE "B" CONCRETE ENDWALLS, BILL OF STEEL FOR STEEL PIPES (PIPE SIZES 15" TO 78", ALL SKEWS, 4:1 SLOPE)CROSS DRAIN ENDWALLS PLACED OUTSIDE THE CLEAR ZONE MAY USE TYPE B
D-PE-15ATYPE "U" CROSS DRAIN ENDWALL FOR 15" PIPE (FOR 3:1, 4:1 & 6:1 SLOPES)FOR END WALL GEOMETRY
D-PE-18ATYPE "U" CROSS DRAIN ENDWALL FOR 18" PIPE (FOR 3:1, 4:1 & 6:1 SLOPES)FOR END WALL GEOMETRY
D-PE-24ATYPE "U" CROSS DRAIN ENDWALL FOR 24" PIPE (FOR 3:1, 4:1 & 6:1 SLOPES)FOR END WALL GEOMETRY
D-PE-30ATYPE "U" CROSS DRAIN ENDWALL FOR 30" PIPE WITH STEEL PIPE GRATE (FOR 3:1, 4:1 & 6:1 SLOPES)FOR END WALL GEOMETRY
D-PE-36ATYPE "U" CROSS DRAIN ENDWALL FOR 36" PIPE WITH STEEL PIPE GRATE (FOR 3:1, 4:1 & 6:1 SLOPES)FOR END WALL GEOMETRY
D-PE-42ATYPE "U" CROSS DRAIN ENDWALL FOR 42" PIPE WITH STEEL PIPE GRATE (FOR 3:1, 4:1 & 6:1 SLOPES)FOR END WALL GEOMETRY
D-PE-48ATYPE "U" CROSS DRAIN ENDWALL FOR 48" PIPE WITH STEEL PIPE GRATE (FOR 3:1, 4:1 & 6:1 SLOPES)FOR END WALL GEOMETRY
D-PE-99TYPE "U" CROSS DRAIN ENDWALL DETAILS, PIPE GRATE & SKEWED CONNECTIONFOR GRATE DETAILS
D-SEW-1ATYPE "SAFETY" SIDE DRAIN ENDWALL WITH STEEL PIPE GRATE, FOR 15" THRU 48" PIPES, 6:1 SLOPED-SEW- SERIES STANDARD DRAWINGS WITH SAFETY GRATE
D-SEW-12DTYPE "SAFETY" SIDE DRAIN ENDWALL WITH STEEL PIPE GRATE, FOR 18" PIPES, 12:1 SLOPEALL MEDIAN CROSSOVER SIDE DRAINS (LONGITUDINAL) PLACED UNDER MEDIAN OPENINGS REQUIRE SAFETY ENDWALLS AS SHOWN
D-SEW-SERIESPipe Culverts and Endwalls Standard DrawingsALL SIDE DRAINS (PARALLEL) PLACED UNDER A SIDE ROAD, DRIVEWAY, OR FIELD ENTRANCE, ETC. THAT INTERSECT A MAINLINE ROADWAY, REQUIRE SAFETY ENDWALLS AS SHOWN
S-CZ-1CLEAR ZONE CRITERIAALL CULVERT ENDWALLS LOCATED WITHIN THE CLEAR ZONE

Related Item Numbers

ITEM NO.U/MDESCRIPTION
607-03.02L.F.18" CONCRETE PIPE CULVERT (CLASS III)
607-03.03L.F.18" CONCRETE PIPE CULVERT (CLASS IV)
607-03.04L.F.18" CONCRETE PIPE CULVERT (CLASS V)
607-05.02L.F.24" CONCRETE PIPE CULVERT (CLASS III)
607-05.03L.F.24" CONCRETE PIPE CULVERT (CLASS IV)
607-05.04L.F.24" CONCRETE PIPE CULVERT (CLASS V)
607-06.02L.F.30" CONCRETE PIPE CULVERT (CLASS III)
607-06.03L.F.30" CONCRETE PIPE CULVERT (CLASS IV)
607-06.04L.F.30" CONCRETE PIPE CULVERT (CLASS V)
607-07.02L.F.36" CONCRETE PIPE CULVERT (CLASS III)
607-07.03L.F.36" CONCRETE PIPE CULVERT (CLASS IV)
607-07.04L.F.36" CONCRETE PIPE CULVERT (CLASS V)
607-08.02L.F.42" CONCRETE PIPE CULVERT (CLASS III)
607-08.03L.F.42" CONCRETE PIPE CULVERT (CLASS IV)
607-08.04L.F.42" CONCRETE PIPE CULVERT (CLASS V)
607-09.02L.F.48" CONCRETE PIPE CULVERT (CLASS III)
607-09.03L.F.48" CONCRETE PIPE CULVERT (CLASS IV)
607-09.04L.F.48" CONCRETE PIPE CULVERT (CLASS V)
607-10.02L.F.54" CONCRETE PIPE CULVERT (CLASS III)
607-10.03L.F.54" CONCRETE PIPE CULVERT (CLASS IV)
607-10.04L.F.54" CONCRETE PIPE CULVERT (CLASS V)
607-11.03L.F.60" CONCRETE PIPE CULVERT (CLASS IV)
607-11.04L.F.60" CONCRETE PIPE CULVERT (CLASS V)
607-11.05L.F.60" CONCRETE PIPE CULVERT(CLASS IV)JACKED-IN-PLACE
740-10.03S.Y.GEOTEXTILE (TYPE III)(EROSION CONTROL)

Archived Standard Drawings

DATES OF EACH ARCHIVED DRAWINGS ( THE INITIAL STANDARD DRAWING IS BOLD )
07-12-2007 | 06-01-2009 | 02-01-2012 | 08-21-2012 | 01-02-2013 | 03-16-2017 | 06-28-2019 | 11-30-2020 | 03-04-2021 | 03-01-2023